Very High Cycle, Coal Power Plant Butterfly Valve Application

vane actuator
One moving part. Simply the best.

A coal fired power plant was using old Powell gate valves with dual air cylinders and volume tanks. Because of high cycle rate (the valve cycles open/closed every 30 seconds), the Powell gate valves were breaking down constantly - leaking at first, then failing. Downtime for repair was costing a fortune.
Kinetrol Model 12
Kinetrol Model 12

A local Kinetrol Distributor was called in to recommend a better solution. After discussing the capabilities of Kinetrol, the power plant decided to replace the gate valves with 6" high performance butterfly valves actuated with Kinetrol size 12 actuators, spring returns and limit switch packages. 

The result was a robust valve/actuator package that could handle the 120 cycles per hour required - truly a difficult application. As of two years in operation, both valve and actuator have been running reliably much to the delight of the power plant maintenance crew. 

High cycle coal fired power plant Kinetrol / HPBV application.

Innovative Approach to Add Manual Failsafe Handles for Large Quarter-Turn Valves


manual failsafe unit
Kinetrol manual failsafe unit
Let's assume you have an application where it's critical that a large, pneumatically actuated valve cannot be left unattended in the wrong position (opened or closed). Or maybe your application requires the use of a manual operator with a fire-safe fusible link. The problem though, is the valve you want to control has torque requirements much greater than the output of any manual failsafe unit can provide. 

Here's an innovate and effective way to incorporate a manual failsafe unit on large size ball, butterfly, or plug valves. 

Retrofit your large valve with a 3-way "L" port ball valve and a manual failsafe spring handle on the large valve actuator's inlet air supply port. 

This allows the opening of the valve with the manual failsafe handle. When the handle is released, the valve shuts automatically by venting the air to atmosphere, and allowing the springs in the actuator to close the valve. 

Size limitations on the valves are no longer an issue, and this will work on anyone's pneumatic spring return actuator (spring return required, will not work on double acting actuators). 


Manual Override for Larger Valves
Manual Override for Larger Valves

Limit Switches for Your Rotary Vane Actuator in Hazardous Areas

This Explosion Proof Limit Switch Box offers a wide range of signaling options in a compact corrosion resistant aluminum alloy housing available for close - mounting onto Kinetrol actuators or discrete mounting via a Kinetrol 05 square or industry standard VDI/VDE interface onto any make of rotary actuator. Easy to wire and set up with true industrial robustness.

Internally fitted options include AS interface digital communication and a 4-20mA, 2-wire, modulating angle retransmit circuit. The range of switches and terminal arrangements includes 2 or 4 switches and extra connections - allowing single point termination of wiring for limit switches and solenoid valves. This product is available to mount on Kinetrol models 03 - 30.

Vane Actuator for Pneumatic Power on Roll Lifting Machine

vane actuator on roll lifter
Kinetrol vane actuator on roll lifter.
There are many examples in machine design where the need for pneumatically driven, 90 ° rotation is required. One such application is a coil/roll lifting machine used to lift heavy rolls of material.

The machine is pneumatically operated and provides an expandable shaft that grabs and holds on to the center hole of the roll. The expandable shaft also prevents spiraling while lifting.  The roller can be tilted 90 ° so that it will be retrieved horizontally and vertically. A Kinetrol pneumatic vane actuator is used for the 90 ° movement because it provides very smooth rotation and has exceptional long cycle life.

See the equipment in operation below. Note the function and use of the vane actuator.



Thanks to the equipment manufacturer, JLM Teknik.

Kinetrol Actuators Chosen to "Bust Myths" on Popular TV Show

Kinetrol Actuators on MythBusters
A mechanical "soldier" busting myths.
Kinetrol actuators have a great reputation in many heavy industries such as power generation, chemical processing, and pulp and paper, but here's one industry that's easy to overlook - special effects engineering for television and movie production.

Case in point, the very popular science entertainment show "MythBusters" (produced for the Discovery Channel).

In an episode challenging the concept of destructive harmonics caused by an army marching in unison, MythBusters decided to create an "army" of mechanical feet to march in over a mock bridge. An important requirement was a mechanical rotational movement device that would allow for synchronized movement (simulating the legs of soldiers). Accurate and smooth control of multiple actuators so the cadence could be controlled was crucial.  Enter Kinetrol.

To see a 4 minute clip of the setup, test and results, see Kinetrol in action on the Breakstep Bridge Minimyth here.

Below are some images from the broadcast.

The "army" of marching feet.


One of the test rigs.

Pneumatic Actuator with 180 Degree Rotation for Your Multi-Port Valve

180 degree actuator
180 degree actuator
for multi-port valves.
So you need a pneumatic actuator with more than 90 degrees of rotation - most likely for a multi-port valve, or a custom louver or damper. Here's an excellent solution.

The simplicity and dependability of a 90 degree rotary vane actuator with a 2:1 step-up linkage mounted to the output shaft.

Kinetrol vane actuators provide factory fitted, direct mount linkage units for their models 02, 03, 05, 07, 09, 12, 14 and 16 actuators, giving a neat single unit with no mount kits or brackets. An added benefit is the linkage’s unique geometry gives constant 2:1 step-up, so that the output torque remains constant throughout the actuator's travel.

The all-steel mechanism of the linkage employs rolling contacts to minimize frictional losses and wear, and to maximize life. The linkage is lubricated for life, and encased in a robust, fully sealed die cast alloy casing. Exterior surfaces are protected by a corrosion resistant epoxy stove enamel finish. 

Standard adjustable end-stops on the 90 degree actuator can be used to set the angle of travel. The other end of the 90 degree actuator allows the full range of Kinetrol modular accessories to be fitted directly.

120 degree actuators are also available with adjustable end stops to give up to 133°.

Keeping Critical Turbine Lubrication Flowing

Kinetrol actuator on lube skid
Lube filter diverters
(courtesy of Kinetrol USA)
Power plants generate power 24/7. Their generator turbines are constantly running.  Turbines require lubrication to protect against wear and also for cooling. Maintenance of the lubrication system is critical, and switching between two lube skids is a common way to perform maintenance without shutting down the turbine.

Two 3-way valves and pneumatic actuators are used to re-direct flow between between two lube filter housings. The valve and actuator must be extremely reliable as a failure requires the turbine shutting done.

Steam Turbine
Steam Turbine
(courtesy of Wikipedia)
The automated valves provides an “on-the-fly” ability to transfer turbine oil service between filters, allowing the unit to run, and maintenance to be performed on the filter not in service. This is an extremely critical service to protect the turbine.